Used in some plumbing code areas to connect a reducing branch line into a vertical drain pipe instead of a conventional tee fitting.

Reducing Combination Tee-Wye (HUB x HUB x HUB)

Used in some plumbing code areas to connect a reducing branch line into a vertical drain pipe instead of a conventional tee fitting. Also, is the acceptable method of connecting a horizontal branch pipe approaching a horizontal drain pipe on the perpendicular.

(Can be made from a wye and a "Street Eighth Bend").

Part #
Size Box Qty
Box Weight
82521 2" x 2" x 1 1/2"
10 4
82531 3" x 3" x 1 1/2"
10 11
82532 3" x 3" x 2"
10 11
82542 4" x 4" x 2"
10 14
82543 4" x 4" x 3"
5 13
Used when connecting a branch line into a vertical drain pipe.

Sanitary Tee (HUB x HUB x HUB)

Used when connecting a branch line into a vertical drain pipe.

Part #
Size Box Qty
Box Weight
81115 1 1/2"
20 5
81120 2" 20 8
81130 3" 20 25
81140 4" 10 21
Used when connecting a branch line into a vertical drain pipe.

Sanitary Tee (SPIGOT x HUB x HUB)

Used when connecting a branch line into a vertical drain pipe.

Part #
Size Box Qty
Box Weight
86115 1 1/2"
50 11
86120 2" 20 6
86130 3" 10 10

Reducing Sanitary Tee (HUB x HUB x HUB)

Used when connecting a reducing branch line into a vertical drain pipe.

Part #
Size Box Qty
Box Weight
81123 2" x 1 1/2" x 1 1/2"
50 15
81122 2" x 1 1/2" x 2"
20 8
81121 2" x 2" x 1 1/2"
20 7
81131 3" x 3" x 1 1/2"
20 14
81132 3" x 3" x 2"
20 16
81142 4" x 4" x 2"
10 12
81143 4" x 4" x 3"
10 17
Used in some plumbing code areas to connect two branch lines into a vertical drain pipe.

Double Fixture Tee (ALL HUB)

Used in some plumbing code areas to connect two branch lines into a vertical drain pipe.

Part #
Size Box Qty
Box Weight
82620 2" 20 12
Used in some plumbing code areas to connect a reducing  branch line into a vertical drain pipe.

Reducing Double Fixture Tee (ALL HUB)

Used in some plumbing code areas to connect a reducing  branch line into a vertical drain pipe.

Part #
Size Box Qty
Box Weight
82621 2" x 1 1/2" x 1 1/2" x 1 1/2"
25 10
Used to bring two branch lines into a vertical drain pipe.

Double Sanitary Tee (ALL HUB)

Used to bring two branch lines into a vertical drain pipe.

Part #
Size Box Qty
Box Weight
83515 1 1/2"
20
6
83520 2" 15 8
83530 3" 10 15
83540 4" 5 14
Used to bring two branch lines into a vertical drain pipe.

Reducing Double Sanitary Tee (ALL HUB)

Used to bring two branch lines into a vertical drain pipe.

Part #
Size Box Qty
Box Weight
83521 2" x 2" x 1 1/2" x 1 1/2"
15 7
83531 3" x 3" x 1 1/2" x 1 1/2"
10 8
83532 3" x 3" x 2" x 2"
10 10
Used at the base of a vertical drain pipe to provide a cleanout opening flush with the finished wall.

Test Tee w/Cleanout Plug (HUB x HUB x FIP)

Used at the base of a vertical drain pipe to provide a cleanout opening flush with the finished wall. PTFE thread tape is recommended for threaded joints.

Part #
Size Box Qty
Box Weight
81315 1 1/2"
10 3
81320 2" 10 4
81340 4" 10 19
Used in conjunction with a threaded plug to provide a cleanout opening. PTFE thread tape is recommended for threaded joints.

Test Tee (HUB x HUB x FIP)

Used in conjunction with a threaded plug to provide a cleanout opening. PTFE thread tape is recommended for threaded joints.

Part #
Size Box Qty
Box Weight
81416 1 1/2"
10 3
81421 2" 10 4
81431 3" 10 8
81441 4" 10 16
Used with vertical drain pipe stack, this fitting provides for above ground level access to piping.

Two-Way Cleanout Tee (HUB x HUB x HUB)

Used with vertical drain pipe stack, this fitting provides for above ground level access to piping.

Part #
Size Box Qty
Box Weight
81633 3" 10 16
81644 4" 5 15
Used primarily in vent lines. Used where flow characteristics are not a primary consideration.

Vent Tee (HUB x HUB x HUB)

Used primarily in vent lines. Used where flow characteristics are not a primary consideration.

Part #
Size Box Qty
Box Weight
81415 1 1/2"
10 3
81420 2" 10 3
81430 3" 10 10
81440 4" 10 20
Conventional threaded cleanout fitting solvent welds into fitting hub and adapts to male threaded plug.

Fitting Cleanout Body (SPIGOT x FIP)

Conventional threaded cleanout fitting solvent welds into fitting hub and adapts to male threaded plug. PTFE thread tape is recommended for threaded joints.

Part #
Size Pkg Qty
Box Qty
Box Weight
81614 1 1/2"
20 100 10
81619 2" 20 100 11
81629 3" 20 7
81639 4" 10 6
Solvent welds into fitting hub to provide access to piping. PTFE thread tape is recommended for threaded joints.

Fitting Cleanout w/Threaded Plug (SPIGOT x FIP)

Solvent welds into fitting hub to provide access to piping. PTFE thread tape is recommended for threaded joints.

Part #
Size Pkg Qty
Box Qty
Box Weight
81615 1 1/2"
20 100 14
81620 2" 20 100 17
81630 3" 25 13
81640 4" 10 9
Fitting fits into Sch. 40 DWV pipe and is used to provide access to piping.

Snap-In Cleanout w/Plug

Fitting fits into Sch. 40 DWV pipe and is used to provide access to piping.

Part #
Size Box Qty
Box Weight
89340 4" 10 4
Used to form a removable closure. These threaded plugs offer a corrosion proof alternative to metal plugs.

Threaded Plug (MIP)

Used to form a removable closure. These threaded plugs offer a corrosion proof alternative to metal plugs. PTFE thread tape is recommended for threaded joints.

Part #
Size Pkg Qty
Box Qty
Box Weight
81814 1 1/4"
20 100 3
81815 1 1/2"
20 100 5
81820 2" 20 100 7
81830 3" 20 100 17
81835 3 1/2"
20 5
81840 4" 10 3

P    800–521–7488

F     8107441653

 

 

Genova Products, Inc. World Headquarters

7034 E Court St

Box 309

Davison, MI 48423-0309

Copyright 2016 Genova Products, Inc. All Rights reserved.

customer service icon

Submitting Form...

The server encountered an error.

Form received.

Used in some plumbing code areas to connect a reducing branch line into a vertical drain pipe instead of a conventional tee fitting.
Used when connecting a branch line into a vertical drain pipe.
Used when connecting a branch line into a vertical drain pipe.
Used in some plumbing code areas to connect two branch lines into a vertical drain pipe.
Used in some plumbing code areas to connect a reducing  branch line into a vertical drain pipe.
Used to bring two branch lines into a vertical drain pipe.
Used to bring two branch lines into a vertical drain pipe.
Used at the base of a vertical drain pipe to provide a cleanout opening flush with the finished wall.
Used in conjunction with a threaded plug to provide a cleanout opening. PTFE thread tape is recommended for threaded joints.
Used with vertical drain pipe stack, this fitting provides for above ground level access to piping.
Used primarily in vent lines. Used where flow characteristics are not a primary consideration.
Conventional threaded cleanout fitting solvent welds into fitting hub and adapts to male threaded plug.
Solvent welds into fitting hub to provide access to piping. PTFE thread tape is recommended for threaded joints.
Fitting fits into Sch. 40 DWV pipe and is used to provide access to piping.
Used to form a removable closure. These threaded plugs offer a corrosion proof alternative to metal plugs.

P     800–521–7488

F     8107441653

 

 

Genova Products, Inc.

7034 E Court St

Box 309

Davison, MI 48423-0309

customer service icon
customer service icon

inquiry@genovaproducts.com

P    800–521–7488

F    8107441653

Genova Products, Inc.